LED Drivers Explained: Constant Voltage vs Constant Current, and How to Size One
12 min read
The short answer
An LED driver turns 230V mains into the steady low voltage DC that LEDs need. LED strip and anything labelled 12V or 24V needs a constant voltage driver: add up the watts and allow about 20% headroom. Panels, downlights and modules labelled in mA need a constant current driver: match the current exactly and check the LED voltage sits inside the driver's window. For dimming, match the driver to the control.
Key takeaways
- Constant voltage (12V or 24V) for strip and modules labelled in volts; constant current (for example 700mA) for panels, downlights and COB modules.
- Size a constant voltage driver so the load is no more than about 80% of its rating.
- For constant current, match the mA exactly and check the LED voltage fits the driver's output window.
- A driver only dims from the signal it is built for: TRIAC, 1-10V, 0-10V, DALI, push dim or DMX.
- Fit drivers where they can breathe and be replaced, and use IP65 or IP67 drivers anywhere damp.
On this page
- What is an LED driver?
- LED driver, transformer or power supply: is there a difference?
- Constant voltage vs constant current: what is the difference?
- How do I read an LED driver label?
- How do I size a constant voltage LED driver?
- How do I choose a constant current LED driver?
- Which dimmable LED driver do I need?
- Where should the driver go?
- Common LED driver problems
- The short version
- Common questions
What is an LED driver?
An LED driver is the power supply that turns 230V mains into the low voltage DC that LEDs run on, and keeps it steady. LEDs are sensitive: a little too much current and they run hot and fail early, too little and they dim or flicker. The driver controls that. Every LED light has one. In a GU10 lamp, a batten or a high bay it is built in, so you never see it. In LED strip, many panels and downlights, and 12V systems, it is a separate box that you choose and wire.
There are two kinds, and picking the wrong one is the most common driver mistake we see:
- Constant voltage (CV) drivers hold a fixed voltage, usually 12V or 24V. They power LED strip, 12V and 24V modules and anything labelled with a voltage.
- Constant current (CC) drivers hold a fixed current, such as 350mA, 700mA or 1050mA. They power LED panels, downlights, COB modules and anything labelled with a current in mA.
The rest of this guide covers how to tell which you need, how to read the label, how to size an LED driver with the right headroom, and which dimmable driver works with which control.
LED driver, transformer or power supply: is there a difference?
For LEDs, the three names usually mean the same thing. People search for an "LED transformer" or a "12V LED power supply" when they mean a constant voltage LED driver. The difference that matters is with old halogen transformers. Those give a low voltage AC output and are designed around a minimum load, often 20W or more, which a few small LED lamps do not reach. That mismatch is a classic cause of flicker on 12V MR16 spotlights, which we cover in why LED lights flicker, buzz or glow. If you are changing 12V halogen to LED, replace the halogen transformer with an LED driver sized for the new load.
Why did my LED light arrive without a driver?
Because the product is a low voltage part of a system, not a mains light. A reel of 24V strip, a 12V cabinet light or a separate LED module needs a driver to go with it, and the listing will show the input as 12V DC, 24V DC or a current in mA. A fitting that plugs straight into the mains lists its input as 220 to 240V AC, or AC230V, and has its driver inside. Check the input line in the spec table before you order, and order the driver at the same time.
Constant voltage vs constant current: what is the difference?
A constant voltage driver fixes the voltage and lets the load draw the current it needs. A constant current driver fixes the current and lets the voltage float to whatever the LEDs need.
| Constant voltage (CV) | Constant current (CC) | |
|---|---|---|
| What stays fixed | Output voltage, for example 12V or 24V | Output current, for example 700mA |
| Label shows | "24V DC", a maximum current in A and a maximum power in W | "700mA" with a voltage window, for example 9 to 42V DC |
| Typical loads | LED strip, 12V or 24V modules, under-cabinet lights | LED panels, downlights, COB modules, track heads |
| How you wire loads | In parallel: each length of strip connects across the same 24V | In series: one loop through the LEDs, or a single module |
| Sizing rule | Total load in watts, plus about 20% headroom | Current must match exactly; the LED voltage must sit inside the window |
| Ledison range | 12V and 24V drivers from 12W to 600W | Constant current drivers from 180mA to 1400mA |
Get this right
Never connect a constant current driver to LED strip, or a constant voltage driver to a bare LED module or panel. A CC driver can push its open circuit voltage, often 50V or more, into a 24V strip, and a CV driver has nothing to stop a module drawing too much current. Either way the LEDs fail, often within seconds.
How do I read an LED driver label?
Match the output side to the LEDs and the input side to the supply. These are the figures that matter, using real examples from our range.
| Label item | What it means | Example |
|---|---|---|
| Input voltage | The supply it runs on. 220 to 240V AC is UK mains. | 100 to 240VAC on our Glacial strip drivers |
| Output voltage (CV) | Must equal the strip or module voltage exactly | 12V or 24V DC |
| Output current (CC) | Must equal the LED's rated current | 700mA |
| Voltage window (CC) | The range of LED voltages it can drive at that current | 9 to 42V DC at 700mA on the Euchips 30W |
| Rated power | The most it can deliver. Size your load below it. | 120W |
| DIP switch settings | Selectable output currents on one driver | 0.5A to 1.1A in 13 steps on the Boke 40W |
| No load output voltage | The voltage on the output with nothing connected | 54V DC on the Boke 40W |
| Ripple | How smooth the output is. Lower means less flicker. | 1% on the Boke 40W |
| IP rating | Protection against dust and water | IP20 indoor, IP67 on our metal cased drivers |
| SELV or Class II | The output is safety extra low voltage, or the driver is double insulated | SELV on the Philips Xitanium |
| Inrush current | The brief surge at switch on. Limits how many drivers share one breaker. | 40 Xitanium 44W drivers per 16A type B MCB |
How do I size a constant voltage LED driver?
Add up the watts of everything on the driver and choose a driver rated at least 20% above that. Running a driver flat out makes it hot, and heat shortens its life. Most installers aim to load a driver to no more than about 80% of its rating.
- Find the load. LED strip is rated in watts per metre. Multiply by the length. For example, 8m of strip at 10W per metre is 80W.
- Add headroom. 80W ÷ 0.8 = 100W. You need a driver of at least 100W.
- Pick the next size up. In our range that is a 120W driver, such as the Glacial GP-TH120N-24V if you want to dim it from a wall dimmer, or a 200W driver if you plan to add more strip later.
- Check the voltage. A 24V strip needs a 24V driver. A 12V driver will barely light it; a 24V driver on 12V strip will burn it out.
- Plan long runs. Strip loses voltage along its length, so the far end can look dimmer. Check the maximum run on the strip listing and feed long runs from both ends, or from the middle. For the same watts, 24V strip draws half the current of 12V, so it suffers less from voltage drop.
One big driver or several small ones?
One driver per zone is simpler to dim and to fault find. Several smaller drivers close to the strip keep the low voltage runs short, which helps with voltage drop. Our Glacial range covers both: small screw terminal drivers from 12W for a cabinet, up to 600W IP67 metal cased drivers for long runs and commercial jobs.
How do I choose a constant current LED driver?
Match the current exactly, then check the LED voltage sits inside the driver's window. Power follows from those two: current x voltage.
- Read the LED or the old driver. A panel or downlight module is labelled with its current, for example 700mA, and a forward voltage or voltage range, for example 30V. The old driver's output label tells you the same.
- Match the current. Same mA, or a DIP switch setting that gives it. Too high overdrives the LEDs; too low makes them dim.
- Check the window. At 700mA, the Euchips EUP30T works from 9 to 42V, so a 30V module fits.
- Check the power. 0.7A x 30V = 21W, inside that driver's 30W rating.
- Check the dimming. Choose non-dimmable, TRIAC, 1-10V or DALI to suit the control (see the table below).
Replacing a failed driver in a panel or downlight is a common job. Our Boke and Lifud replacement drivers are made for it, from 180mA up to 1400mA, and several have DIP switches so one driver covers several currents. If the old driver's label is unreadable, the LED board itself often has the current printed on it. If you cannot find either, do not guess: ask us with a photo of the fitting.
Which dimmable LED driver do I need?
The one that matches your control. A driver only dims from the type of signal it is built for. A mains dimmer will not dim a 1-10V driver, and a 1-10V dimmer will not dim a TRIAC driver.
| Dimming type | How it is controlled | Best for | Examples in our range |
|---|---|---|---|
| TRIAC or phase cut | A mains LED dimmer switch, leading or trailing edge, on the 230V side | Homes, replacing a light switch with a dimmer, no extra wiring | TRIAC drivers: Glacial 24V 40W and 120W (CV), Euchips 15W to 45W and Mean Well PCD-25 (CC) |
| 1-10V or 0-10V | A separate two wire low voltage control from a 1-10V dimmer or controller | Commercial rooms, sensors, simple zones | 1-10V drivers: Euchips EUP and Easeic LNA series (CC); Glacial 3-in-1 (CV) |
| DALI and DALI-2 | A digital two wire bus, each driver addressable | Offices, schools, larger buildings, emergency monitoring | DALI drivers: Easeic LND, Euchips EUP D series, Mean Well LCM-25DA, Philips Xitanium TD |
| Push dim | A mains retractive (push to make) switch on the driver's control terminals | A simple dim and switch from one button, no dimmer needed | Many of our DALI drivers also accept push dim |
| PWM or resistance | A PWM signal or a variable resistor | Panel builders, special controls | Glacial 3-in-1 and many 1-10V drivers |
| DMX512 and RDM | A DMX lighting desk or controller | Stage, events, architectural colour effects | Euchips DMX drivers, 20W and 50W CC, 135W and 150W three channel CV |
Many of our drivers take more than one signal. The Easeic LND drivers accept DALI-2, 1-10V, PWM and push dim, and the Boke BK-DUL042 accepts DALI-2, push dim and 1-10V, which gives you a fallback if the control plan changes.
Where should the driver go?
- Somewhere you can get to. Drivers fail more often than the LEDs they feed. Fit them where they can be reached and replaced, for example above an access hatch, inside a cupboard or in a plinth that lifts out, not plastered into a ceiling.
- Somewhere with air. Do not bury a driver in loft insulation or seal it in a box with no room around it. Heat is what wears drivers out.
- The right IP rating. IP20 drivers are for dry indoor spaces. Outdoors, in bathrooms, or anywhere damp, use an IP65 or IP67 driver, such as our Glacial metal cased drivers, or put an IP20 driver in a suitable enclosure.
- Close enough to the load. Check the maximum output cable length. The Boke 40W, for example, lists a maximum of 2m.
Common LED driver problems
| What happens | Likely cause | What to check |
|---|---|---|
| Strip flashes on and off every second or two | Driver overloaded or a short, so it is cutting out and retrying | Total watts against the driver rating; any short on the strip or joints |
| Far end of the strip is dim or a different colour | Voltage drop on a long run | Feed from both ends or the middle; use 24V; shorter runs per driver |
| Panel or downlight flickers, or only half lights | Driver failing, or wrong current after a replacement | Replacement current and voltage window against the LED label |
| Lights flicker or buzz when dimmed | Dimmer and driver do not match, or the load is too small for the dimmer | Dimming type; see our flicker guide |
| Driver is very hot | Overloaded, or no airflow around it | Load under about 80% of rating; space around the driver |
Safety: when to call an electrician
The mains side of every LED driver is 230V. Isolate the circuit at the consumer unit before you connect or replace one. Plug-in adaptors aside, fitting a driver means connecting to fixed wiring, which should be done by a qualified electrician, and in England and Wales some electrical work in homes is notifiable under Part P of the Building Regulations. Always connect the LED side of a constant current driver before you switch the mains on, and never work on the output with power applied.
For installers
- Philips Xitanium 44W: CC, 0.9, 0.95, 1.0 or 1.05A (1050mA default), 30 to 42V, SELV, 40 drivers per 16A type B MCB.
- Mean Well LCM-25 (0-10V) and LCM-25DA (DALI): CC, 350mA to 1050mA in six steps (700mA default); 26 units on a type B or 44 on a type C 16A breaker for the LCM-25.
- Boke BK-PBL040S: 40W CC, 0.5A to 1.1A by DIP switch in 13 levels, 28 to 42V, 1% ripple, 54V no load, optional emergency support, 2m maximum output cable.
- Euchips EUP T series (TRIAC CC): 15W, 20W, 30W and 45W, DIP switch current, compatible with major phase cut dimmer brands as listed on each spec table.
- Glacial CV range: 12V and 24V, 12W screw terminal Class II up to 600W IP67 metal case; 120W and 40W 24V TRIAC dimmable; 200W and 400W 3-in-1 (0-10V, PWM, resistance).
The short version
An LED driver turns mains into steady low voltage DC. Strip and anything labelled 12V or 24V needs a constant voltage driver: add up the watts and allow about 20% headroom. Panels, downlights and modules labelled in mA need a constant current driver: match the current exactly and check the LED voltage fits the window. Match the dimmable driver to the control, fit the driver where it can breathe and be replaced, and use an IP65 or IP67 driver anywhere damp. Leave the mains connection to an electrician.
Products that help
24V Dimmable LED Driver 120W
From £52.95
40W Constant Current LED Driver
From £18.99
TRIAC Dimmable LED Driver 30W
From £27.99
24V LED Driver 200W
From £55.99
See all LED Strip Drivers 12V & 24V · See all Constant Current LED Drivers · See all AC Dimmable Power Supplies · LED Strip Lights: The Complete Guide to Tape, Drivers and Profiles · DALI Lighting, 0-10V and 1-10V Dimming Explained for Installers · How to Replace Halogen Downlights with LED: GU10, MR16 and Transformers
Common questions
What is an LED driver?
The power supply that converts mains AC into the low voltage DC an LED needs, and keeps the voltage or current steady. Some are built into the light, others are a separate box.
What is the difference between constant current and constant voltage LED drivers?
A constant voltage driver holds a fixed voltage, such as 24V, for strip and modules. A constant current driver holds a fixed current, such as 700mA, for panels and downlights, and lets the voltage vary within a window.
What size LED driver do I need?
Add up the watts of everything on the driver and divide by 0.8. For 80W of strip you need at least a 100W driver, so the next standard size up.
Is an LED driver the same as a transformer?
For LEDs the terms are used for the same thing. Old halogen transformers are different: they give AC and need a minimum load, which is why they often make LED lamps flicker.
Can I use a 24V driver with 12V LED strip?
No. The driver voltage must match the strip exactly. 24V will burn out 12V strip, and 12V will barely light 24V strip.
How do I replace an LED panel driver?
Read the output current and voltage on the old driver or the LED board, then choose a constant current driver with the same current, a voltage window that covers it, and the same dimming type.
Why does my LED strip flash on and off?
Usually the driver is overloaded or there is a short, so it cuts out and retries. Check the total watts against the driver rating and inspect the strip and joints.
Planning a lighting project?
Need a part matched, a datasheet or a price for a large order? Call us or send a message.