LED High Bay Lighting: UFO vs Linear, Lux Levels and Payback for Warehouses
10 min read
The short answer
Use round UFO high bays over open floors and linear high bays over racking aisles and long rows. Size the wattage from the mounting height: about 100W at 4m to 6m, 150W at 6m to 8m and 200W at 8m to 10m. Count fittings from the lux level the task needs, about 150 lux for aisles and 300 for workshops, use narrow beams between racks, and add sensors or dimming for the biggest savings.
Key takeaways
- UFO high bays suit open floors; linear high bays suit aisles, long rows and lower glare.
- Roughly 100W at 4m to 6m, 150W at 6m to 8m, 200W at 8m to 10m, 240W and up above 10m. Compare lumens, not watts.
- Typical targets: 100 to 150 lux for storage and aisles, 300 for workshops and packing, 500 for offices.
- Lumens needed = lux x area ÷ about 0.6; get a proper lighting calculation on bigger jobs.
- Narrow beams in racking aisles and sensors in empty aisles often save as much as the LED itself.
On this page
- High bay lighting in brief
- UFO or linear: which LED high bay lights should you choose?
- What wattage high bay light for my ceiling height?
- What lux level does a warehouse need?
- How many high bay lights do I need?
- Which beam angle for racking aisles?
- Sensors and dimming: where the real savings are
- How quickly do LED high bay lights pay back?
- The short version
- Common questions
High bay lighting in brief
High bay lighting is the fitting you hang from a high roof, usually 6m and up, in warehouses, factories, workshops, sports halls and big retail sheds. LED high bay lights come in two shapes: round UFO high bays, which suit open floors, and linear high bays, which suit aisles, long bays and anywhere glare matters. Choose the wattage from the mounting height, the number of fittings from the lux level the task needs, and the beam angle from the layout: wide for open floors, narrow for racking aisles. Then add sensors or dimming, because in most warehouses that saves as much as the LED itself.
This guide covers:
- UFO vs linear high bay lights
- Mounting height to wattage
- Lux levels for warehouses, workshops, retail and offices
- How many high bays you need, with a worked example
- Beam angles for racking aisles
- Sensors, 1-10V and DALI
- Energy and payback
UFO or linear: which LED high bay lights should you choose?
UFO for open floors and big square bays, linear for aisles, long rows and lower glare. Both do the same job. The difference is how the light leaves the fitting.
| UFO (round) high bay | Linear high bay | |
|---|---|---|
| Light pattern | Round pool, wide beam | Long rectangle, lines up with aisles and rows |
| Best for | Open floors, loading bays, sports halls, factories with no racking | Racking aisles, production lines, workshops, retail sheds |
| Glare | Very bright point source unless it has a diffuser or reflector | Spread over a longer face, so usually more comfortable |
| Mounting | Hook, eye bolt or bracket on one point | Two point suspension, or surface mount |
| Typical Ledison range | 100W to 240W, IP65 | 60W to 250W, many IK10 |
| Options | Switchable power and colour, sensor sockets, 1-10V or Bluetooth | 1-10V dimming, emergency packs, narrow aisle optics |
If the space has racking, start with linear. If it is open, a UFO is quicker to hang and does the job with fewer fittings. Many sites end up with both: linear down the aisles, UFO over the loading bay.
What wattage high bay light for my ceiling height?
Roughly 100W at 4m to 6m, 150W at 6m to 8m, 200W at 8m to 10m and 240W or more above 10m. Light spreads as it travels, so the higher the fitting, the more lumens you need to keep the same level on the floor. Use this table as a starting point, then check it against the lux level you need.
| Mounting height | Typical LED wattage | Typical light output | Typical spacing |
|---|---|---|---|
| Under 4m | Use battens, tri-proof fittings, panels or LED trunking rather than high bays | 2,000 to 8,000 lm per fitting | 1.5m to 3m |
| 4m to 6m (low bay) | 60W to 100W | 6,500 to 16,000 lm | 4m to 6m |
| 6m to 8m | 150W | 15,000 to 24,000 lm | 6m to 8m |
| 8m to 10m | 200W | 22,800 to 32,000 lm | 7m to 10m |
| 10m to 12m and above | 240W to 250W | 30,000 to 38,400 lm | 8m to 12m, narrower beams |
Spacing of about one to one and a half times the mounting height gives an even floor. Go closer for higher lux levels or where racking blocks the light. Lumen ranges above come from our own fittings, which give from about 105 to 160 lumens per watt depending on model, so always compare lumens rather than watts.
What lux level does a warehouse need?
About 100 to 150 lux for storage and aisles, 300 lux for packing and general workshop work, 500 lux for offices and assembly, and 750 lux or more for fine inspection. Lux is the amount of light falling on a surface: one lumen per square metre. The figures below are typical UK design targets taken from the lighting design guidance used by designers. The Health and Safety Executive publishes its own guidance, Lighting at work (HSG38), which sets out minimum levels for safety; good design normally aims well above those minimums.
| Area or task | Typical design target (maintained average) |
|---|---|
| Bulk storage, stock rooms not continuously occupied | 100 lux |
| Manned gangways between racking (at floor level) | 150 lux |
| Loading bays, dispatch areas | 150 to 200 lux |
| Stores continuously occupied, picking | 200 lux |
| Packing, general workshop, rough assembly | 300 lux |
| Retail sales floor | 300 to 500 lux |
| Offices, reading and screen work, medium assembly | 500 lux |
| Fine assembly, inspection, colour checking | 750 lux and above, often local task lighting |
| Sports halls | Depends on sport and level of play; check the governing body's guidance |
"Maintained" means the level you still have after the lamps have aged and the fittings have collected dust, so designers start higher than the target. Ask your lighting designer or the client's health and safety lead which figures apply to the site, especially where machinery or forklifts operate.
Get this right
Glare matters as much as lux. A very bright point source above a forklift driver or a warehouse picker is hard to work under. Use linear fittings, diffusers or reflectors over working areas, and look for UGR below 19 on fittings over desks and screens.
How many high bay lights do I need?
Lumens needed = target lux x floor area ÷ about 0.6, then divide by the lumens of one fitting. The 0.6 allows for light lost to walls, racking, roof colour, and the drop in output over time. A clean shed with light walls may manage 0.7; a dusty workshop with dark steel may be nearer 0.5.
Worked example: 600m² workshop at 7m
- Floor: 30m x 20m = 600m². Task: general workshop, target 300 lux.
- Lumens needed: 300 x 600 ÷ 0.6 = 300,000 lm.
- Mounting height 7m points to 150W fittings. Our 150W Pyron linear high bay gives 24,000 lm.
- Fittings: 300,000 ÷ 24,000 = 12.5, so 13. Lay out a regular grid: three rows of five (15 fittings) at about 6m centres gives an even floor with a margin for ageing.
- Check: 15 x 150W = 2.25kW for 600m², or about 3.75W per m².
For anything more than a simple shed, ask for a lighting calculation in software such as DIALux or Relux. It takes the room shape, racking, reflectances and the actual photometric file into account, and it is what most commercial clients expect to see.
Which beam angle for racking aisles?
Narrow or asymmetric beams in aisles, wide beams over open floors. A standard high bay has a beam of about 110° to 120°. Over an open floor that is ideal. Over a narrow aisle between tall racking, much of that light lands on the tops of the racks, and the floor and the lower shelves stay dark.
Our LuxeBay 240W linear high bay is built for this: it gives 38,400 lumens at 160 lumens per watt and comes with a choice of optics including 30°, 60° and 90°, and asymmetric 30 x 70°, 40 x 130° and 60 x 90° beams, so you can match the beam to the aisle width and racking height. Run linear fittings along the aisle, not across it, and centre them over the aisle.
Sensors and dimming: where the real savings are
Most warehouse aisles are empty most of the time. A motion sensor that dims or switches lights in empty aisles often saves as much again as the move to LED, and LED, unlike metal halide or high pressure sodium, can switch and dim instantly with no warm up.
- On/off sensors. Simple and cheap, good for stores and rooms that are either in use or empty. Our Hytronik HC049S PIR sensor bolts onto high bays, is rated IP65 and works up to 12m mounting height.
- Corridor or step dimming. Lights drop to a low standby level, say 10% to 30%, instead of switching off, so the aisle never goes dark. The Merrytek MC054V microwave and daylight sensor for our Attica trunking gives 2 or 3 step dimming with 1-10V drivers, at up to 15m.
- Daylight dimming. Near rooflights and windows, a daylight sensor dims fittings when there is enough natural light.
- 1-10V and DALI. For whole buildings, a control system lets you group, schedule and dim. Several of our high bays are 1-10V dimmable, including the Paragon, which also has a Zhaga socket for a plug-in sensor, and the Zeus 150W and 240W linear high bays. For more on choosing between them, see the DALI and 1-10V guide in this series.
How quickly do LED high bay lights pay back?
Usually within a few years on a site lit for long hours, faster with sensors. You can work it out from three numbers: the power saved, the hours of use, and your unit rate.
Worked example: 20 metal halide high bays to LED
| Old: 400W metal halide | New: 150W LED | |
|---|---|---|
| Power per fitting, including control gear | About 440W | 150W |
| 20 fittings | 8.8kW | 3.0kW |
| Hours per year (12 hours a day, 5 days a week) | 3,120 | 3,120 |
| Energy per year | About 27,500 kWh | About 9,400 kWh |
| Saving | About 18,100 kWh a year, before sensors | |
To get the payback in years, divide the installed cost of the new lights by the yearly saving in pounds: payback = installed cost ÷ (kWh saved x your unit rate). Use the unit rate on your business electricity bill. Then add the savings you do not see on the meter: no more relamping at height, and no more hiring an access platform every year to change failed lamps.
Sensors change the sums again. If aisles are empty half the time and dim to 20% when empty, the LED energy in the example drops by roughly a further 40%.
Safety: when to call an electrician
High bay installations are commercial electrical work. Have them designed and installed by a qualified electrician or contractor, with a lighting calculation for the space, emergency lighting where it is needed, and safe working at height. Check the suspension: each fitting must hang from a fixing rated for its weight, with a secondary safety wire where the manufacturer asks for one. Large numbers of LED drivers switching on together draw a high inrush current, so check the number of fittings per circuit breaker against the driver data.
For installers
- Skyline linear high bays: 60W 6,540 lm (IP65), 100W 10,500 lm, 150W up to 18,000 lm, 200W up to 25,000 lm; Mean Well drivers (SLG60, SLG150, HLG-240H); IK10 diffuser; 100 to 305VAC.
- Pyron linear high bays: 100W 16,000 lm, 150W 24,000 lm, 200W 32,000 lm; 160 lm/W; honeycomb reflector; IP65, IK10; suspended or surface; optional 3 hour emergency pack on 150W and 200W.
- LuxeBay 240W: 38,400 lm, 160 lm/W, IP65, IK10; optics 30°, 60°, 90°, 30 x 70°, 40 x 130°, 60 x 90°; surface mount adjustable ±45°.
- Paragon UFO: 100W, 150W or 200W switchable (15,000, 22,500 or 30,000 lm); 3000K, 4000K or 5000K selectable; IP65, IK08; 1-10V; Zhaga sensor socket; 110° beam, 60° and 90° on request.
- SOFOS UFO: adjustable 100W to 200W, up to 28,000 lm, UGR below 19, mounting height 3m to 15m, Bluetooth or microwave sensor options.
- Attica trunking: 1437mm modules, UGR below 19, non-dimmable, 1-10V or DALI versions, self-contained emergency versions, 5 and 7 wire connectors.
For street and area lighting outside the building, see our Hyperion LED street lighting range. For offices, our LED panels include 600 x 600 models with UGR below 19 and DALI, 1-10V or Triac options. The full range is in commercial lighting.
The short version
Pick UFO high bays for open floors and linear high bays for aisles and long rows. Size the wattage from the mounting height: about 100W at 4m to 6m, 150W at 6m to 8m, 200W at 8m to 10m, more above. Count the fittings from the lux level the task needs, using lux x area ÷ 0.6 as a first check, and get a proper lighting calculation on bigger jobs. Use narrow beams in racking aisles, keep glare down over working areas, and add sensors or dimming: that is where much of the saving comes from. Work out payback from kWh saved, hours and your own unit rate.
Products that help
LED High Bay Light 100W / 150W / 200W Switchable
From £58.95
LuxeBay LED High Bay Light 240W
From £117.95
LED Trunking Light 72W
From £77.95
See all LED Linear Bay Lights · See all LED Low/High Bay · See all LED Link Linear Trunking · Garage Lighting Guide: LED Battens, Lumens and How Many You Need · DALI Lighting, 0-10V and 1-10V Dimming Explained for Installers · Emergency Lighting Explained: Maintained vs Non-Maintained, Testing and the Rules
Common questions
What is a high bay light?
A light fitting designed to hang from a high roof, usually 6m and up, in warehouses, factories, workshops and sports halls. Below about 4m, battens, panels or trunking are usually a better choice.
What wattage high bay do I need for a 6m ceiling?
About 100W to 150W, giving roughly 15,000 to 24,000 lumens per fitting, spaced about 6m apart. Check the total against the lux level the task needs.
What lux level does a warehouse need?
Typical design targets are about 100 lux for bulk storage, 150 lux for manned aisles between racking, 300 lux for packing and 500 lux for offices. HSE guidance HSG38 sets out minimum levels for safety.
Are UFO or linear high bays better?
Neither is better everywhere. UFO high bays are quick to hang over open floors; linear high bays line up with aisles and production lines and usually give less glare.
How many high bay lights do I need?
Multiply the target lux by the floor area, divide by about 0.6, then divide by the lumens of one fitting. A 600m² workshop at 300 lux needs about 300,000 lumens, or 13 to 15 fittings at 24,000 lumens.
Can LED high bays be dimmed or used with sensors?
Yes. Many are 1-10V dimmable and take bolt-on or socket sensors. LED switches and dims instantly, unlike metal halide, so sensors in empty aisles save a lot.
How long does LED high bay payback take?
Divide the installed cost by the yearly saving: kWh saved x your unit rate. Replacing 20 400W metal halide fittings with 150W LED saves about 18,000 kWh a year at 3,120 hours.
Planning a lighting project?
Need a part matched, a datasheet or a price for a large order? Call us or send a message.