PIR Sensor Light vs Microwave: Why Your Security Light Keeps Coming On
11 min read
The short answer
A PIR sensor light switches on when it sees a warm body move across its zones; a microwave sensor switches on when anything moves in its radio field, even through glass or thin walls. Most security lights that keep coming on are seeing something real: plants, warm air, animals or traffic. Turn the sensitivity or range down, aim the head across the path, and set the lux dial at dusk.
Key takeaways
- PIR sees heat moving across it, cannot see through glass, and is usually the calmer choice outdoors.
- Microwave sees any movement, works through glass, plasterboard and plastic, and suits corridors, stairs and car parks.
- False triggers almost always have a real cause: moving plants, warm air from a flue or vent, animals, or a road in range.
- A light that stays on usually has the time dial at maximum, constant movement in range, or manual override switched on.
- Cheap floodlights die from water and worn sensor relays, not from the LEDs. Choose IP65 and a properly rated sensor.
On this page
- PIR vs microwave sensor: the short version
- How does a PIR sensor light work?
- What is a microwave sensor on a light?
- Why does my security light keep coming on?
- Why does my PIR sensor light stay on?
- How to adjust a PIR sensor light
- Dusk to dawn, photocell or motion sensor: which do you need?
- Sensors for stairwells, corridors and car parks
- Why do cheap PIR floodlights keep failing?
- If you want the short version
- Common questions
PIR vs microwave sensor: the short version
A PIR sensor light switches on when it sees a warm body move. A microwave sensor light switches on when anything moves inside the radio field it sends out. That one difference explains almost every false trigger, every missed visitor and every light that will not switch off. Pick the right type for the place, set three dials, and most sensor problems go away.
| PIR (passive infrared) | Microwave (high frequency) | |
|---|---|---|
| What it detects | Changes in heat as a warm body crosses its zones | Any movement that reflects its signal |
| Best direction of movement | Across the sensor | Any direction, including straight towards it |
| Through glass or a cover | No. It must see the area directly | Yes, through glass, plasterboard and plastic |
| Hidden inside a fitting | No, it needs its own lens | Yes, often fitted behind the diffuser |
| Hot weather | Less sensitive when the air is close to body temperature | Not affected by air temperature |
| Typical false triggers | Warm air from vents and flues, sun on surfaces, animals | Moving trees, traffic or people beyond a thin wall or fence |
| Typical use | Driveways, porches, gardens, security floodlights | Stairwells, corridors, toilets, car parks, bulkheads, tubes |
How does a PIR sensor light work?
It watches for heat moving between zones. PIR stands for passive infrared. The sensor sends nothing out. Behind the faceted plastic lens is a small element that reacts to infrared, the heat every person, car engine and animal gives off. The lens splits the view into fingers, as in the diagram. When something warmer than the background moves from one finger to the next, the reading jumps and the light switches on.
That design has three consequences you can use:
- Aim it across the path, not along it. Someone walking across the fingers is picked up early. Someone walking straight at the sensor stays in the same finger for longer and is seen late, sometimes only a few steps away.
- It cannot see through glass. Glass blocks the infrared a PIR needs, so a PIR behind a window, or inside a sealed fitting, will not work.
- It needs a temperature difference. On a hot summer evening, when walls and paving are close to body temperature, a PIR becomes less sensitive. On a cold night it is at its best.
What is a microwave sensor on a light?
A tiny radar. A microwave sensor sends out a very low power signal and listens for the echo. When something moves, the echo changes and the light switches on. The Hytronik sensors we sell work at 5.8GHz with a transmitted power below 0.2mW, a small fraction of what a mobile phone uses.
Because the signal passes through non-metal materials, a microwave sensor can sit behind a diffuser, above a plasterboard ceiling or inside a sealed bulkhead. That is why our sensor tubes, sensor bulkheads and ceiling sensors are all microwave types. It also detects movement in any direction, including someone walking straight towards it, which suits corridors and stairs.
The same strength is its weakness. The signal does not stop at the edge of the space you care about. A microwave sensor on a garage wall can see movement on the other side of a thin wall, a timber fence or a window, and a sensitive one by a road can be triggered by passing traffic. The fix is the range setting, not a different light.
Get this right
Outdoors and open to the weather: a PIR aimed across the approach is usually the calmer choice. Indoors, in corridors, stairwells, toilets and car parks, or anywhere the sensor has to hide inside the fitting: choose microwave and turn the range down until it covers only the space you need.
Why does my security light keep coming on?
A light that switches on for no reason is nearly always seeing something real: warm air, a moving branch, a cat or a car. Work through this table before you blame the sensor.
| What happens | Likely cause | Fix |
|---|---|---|
| Comes on at night with nobody there, often in wind | Branches, shrubs or washing moving in range (microwave), or warm air from a boiler flue or vent (PIR) | Cut back plants, aim the sensor away from the flue, reduce sensitivity or range |
| Comes on when cars pass | The road or pavement is inside the detection area | Tilt the PIR head down, or reduce a microwave sensor's range |
| Comes on several times a night | Foxes, cats or birds | Raise the PIR head angle so it looks past ground level close to the house, and reduce sensitivity |
| Comes on in daylight | Lux (daylight) setting turned to maximum or disabled | Turn the lux dial towards the moon symbol and set it at dusk |
| Flashes on and off repeatedly | The light itself, or its reflection, is triggering the sensor, or a spider web on the lens is moving | Angle the lamp away from the sensor, clean the lens, check nothing reflective is in front |
| Comes on during rain or after a storm | Moving water and wet surfaces, or water inside a fitting with a low IP rating | Reduce sensitivity; if water got in, replace with a properly sealed fitting |
Change one thing at a time and test each change with a walk test, described below. If the light still triggers with nothing in range, the sensor is likely faulty.
Why does my PIR sensor light stay on?
A sensor light that will not go off usually has one of four causes.
- The time setting is at maximum. On many units the TIME dial runs from a few seconds to several minutes, and each new movement restarts the countdown. Turn it down and test again.
- It keeps seeing movement. A swaying plant, a flapping cover or warm air from a vent keeps resetting the timer. Fix the cause as in the table above.
- Manual override is on. Many security lights stay on permanently if you switch the wall switch off and on again quickly. Switch off at the wall switch, wait about a minute, and switch back on. Check your model's instructions, as the sequence varies.
- The sensor or its relay has failed. If none of the above works, the switching part inside the sensor may have stuck closed. Replace the sensor or the fitting.
The opposite fault, a sensor light that will not come on, is often the lux setting turned too far towards daylight, a sensor still warming up (our Hytronik sensors take 10 to 30 seconds after power on), or a PIR that cannot see the approach because it is aimed too high or behind glass.
How to adjust a PIR sensor light
Most PIR floodlights and wall lights have three small dials under the sensor head. Labels vary, but they usually read:
- TIME: how long the light stays on after the last movement.
- LUX: how dark it has to be before the sensor will switch the light on. Sun symbol means it works in daylight; moon symbol means only when dark.
- SENS: sensitivity, which on a PIR affects how far it sees.
- Set LUX to the sun (daylight) end, TIME to the minimum and SENS to the middle, so you can test in daylight.
- Aim the head so the approach path crosses the detection area, rather than running straight at it.
- Walk test: walk across the area from the edges inward. Note where the light first comes on.
- Tilt the head down to pull the range in, or up to push it out. Reduce SENS if it reaches the road or the neighbour's garden.
- Set TIME to what you need, often one to three minutes for a driveway.
- At dusk, turn LUX from the sun end towards the moon until the light only works when it is dark enough for you.
Microwave sensors use the same idea with different labels. Hytronik models set detection area as a percentage (10% to 100%), hold time from a few seconds to 30 minutes, and a daylight threshold in lux, by dials, DIP switches or a remote.
Dusk to dawn, photocell or motion sensor: which do you need?
| Control | What it does | Good for |
|---|---|---|
| Photocell (dusk to dawn) | On when it gets dark, off when it gets light | Lighting that should be on all night: shared paths, signage, entrances |
| Motion sensor with daylight sensor | On only when it is dark and something moves | Driveways, porches, side passages, bin stores |
| Corridor or stepped dimming | Full light on movement, then a low standby level, then off or stays low | Stairwells, corridors and car parks where a fully dark space would feel unsafe |
Our sensors range covers all three. The Hytronik DS05 is a daylight sensor only, with thresholds from 2 to 500 lux. The microwave bulkheads combine motion and a photocell. The HEC9025 driver dims to a standby level you choose (10%, 20%, 30% or 50%) instead of switching off.
Sensors for stairwells, corridors and car parks
Shared spaces are where microwave sensors earn their keep. Lights can come on before someone opens the door, they can be hidden inside the fitting, and stepped dimming keeps a low level of light so nobody walks into darkness.
- Corridors and plant rooms with tubes: our microwave sensor tubes are T8 tubes with G13 caps in 4ft and 5ft lengths. They detect up to 10m, hold full light for 30 seconds and drop to a 20% standby level.
- Stairwells and entrances: 2D bulkheads with a microwave sensor and photocell, so they only switch on after dark.
- Offices, toilets and meeting rooms: a flush ceiling sensor such as the Hytronik HMW28 switches the room's lighting circuit, covering up to 8m when ceiling mounted at 3m.
- Warehouses and high ceilings: a bolt-on PIR made for high bays, such as the Hytronik HC049S, rated IP65 and for mounting up to 12m.
Why do cheap PIR floodlights keep failing?
It is a common story: a third PIR floodlight in as many years. The usual reasons are not the LED chips.
- Water gets in. A fitting rated IP44 is only protected against splashes. On an exposed wall that takes driving rain, choose IP65 or better and fit it with the cable entry at the bottom.
- The sensor relay wears out. LED drivers draw a short, high surge of current at switch-on. Look at a sensor's ratings: the Hytronik HC009S switches 800W of resistive load but only 400W of capacitive load, the category LED drivers fall into. A cheap all-in-one floodlight switching many times a night can weld its own relay.
- Heat and sun. A sensor head in full sun all afternoon ages faster. Under the eaves or on a north or east wall is kinder.
For a long life on a busy driveway, a good floodlight such as our security floodlights with a properly rated sensor, mounted out of the worst weather, outlasts a stack of cheap replacements. If your light flickers rather than switching cleanly, see why LED lights flicker.
Safety: when to call an electrician
Adjusting dials and aiming the head is safe for anyone with the power off at the switch. Fitting a new outdoor light, adding a separate sensor to an existing light, or running a new cable outside is electrical work. In England and Wales some of it must be notified under Part P of the Building Regulations, so ask a qualified electrician who can certify it. Turn the circuit off at the consumer unit before opening any fitting.
For installers
- Hytronik HC009S: microwave, 5.8GHz, 220 to 240V, 800W resistive or 400W capacitive, detection up to 12m diameter at 6m height, 30 to 150° angle, hold 10s to 30 min, daylight 5 to 50 lux or disabled, IP20.
- Hytronik HMW28: flush ceiling microwave sensor, 360°, 78mm cut-out, mounting height up to 3m, up to 8m detection ceiling mounted, IP20 (IP54 in the optional surface box).
- Hytronik HC049S: PIR for high bays, IP65, 360°, up to 10m detection, mounting up to 12m, M20 x 1.5 thread, programmed with the HRC-11 remote.
- Outdoors: IP20 microwave sensors go in the clear IP65 box (135mm), which keeps the daylight sensor working.
- Sensor tubes: T8, G13, microwave, 2-step dimming, 30s hold, 20% standby, mounting 2.5 to 10m, no daylight sensor.
If you want the short version
PIR sees warm bodies moving across it, cannot see through glass and is the calmer choice outdoors. Microwave sees any movement, works through covers and suits corridors, stairs and car parks, but its range must be turned down. Most false triggers come from something real in range, and most lights that stay on have the time dial at maximum or manual override on. Water and relay wear, not the LEDs, kill most cheap floodlights.
Products that help
Hytronik HMW28 Ceiling Sensor
From £74.95
LED Flood Light with Sensor 14W
From £43.95
Full Moon LED Outdoor Bulkhead Light 15W 4000K with Microwave Sensor and Photocell
From £64.99
T8 LED Tube 120cm (4ft) 20W with Microwave Motion Sensor
From £31.99
See all Microwave Sensor · See all LED Microwave Sensor Tubes · See all LED Flood Lights - Security · IP Rating Chart: IP44, IP65, IP67 and IP68 Explained for Lights · Motion Sensor Strip Lights for Wardrobes, Stairs and Cupboards: Mains or Battery? · LED High Bay Lighting: UFO vs Linear, Lux Levels and Payback for Warehouses
Common questions
What is the difference between a PIR and a microwave sensor?
A PIR sensor detects body heat moving across its zones and sends nothing out. A microwave sensor sends out a low power signal and detects movement in the echo, so it can see through glass and thin walls and detects movement in any direction.
Why does my security light keep coming on by itself?
Something is moving in range: branches, washing, warm air from a boiler flue, a cat or fox, or traffic. Reduce sensitivity or range, tilt the head down, and move the sensor's view away from the cause.
Why does my PIR sensor light stay on?
The time dial may be at maximum, something may keep moving in range, or manual override may be on. Switch off at the wall for about a minute and back on, then turn the time down. If it still stays on, the sensor has probably failed.
How do I adjust a PIR sensor light?
Set TIME to minimum, LUX to the sun end and SENS to the middle, then walk test across the area and tilt the head until it covers only what you need. Finally set the time you want and turn LUX towards the moon at dusk.
Can a microwave sensor work through glass?
Yes. The signal passes through glass, plasterboard and plastic, which is why microwave sensors can sit inside a fitting. It also means they can see movement beyond a window or thin wall, so set the range carefully.
Do motion sensors work in hot weather?
Microwave sensors are not affected. PIR sensors become less sensitive when the air and surfaces are close to body temperature, so on hot evenings they may pick you up later.
Is a PIR or microwave sensor better for outdoor lights?
Outdoors a PIR aimed across the approach usually gives fewer false triggers, because microwave sensors also react to moving plants and things beyond fences. Microwave suits sheltered entrances, bulkheads and car parks, with the range turned down.
Planning a lighting project?
Need a part matched, a datasheet or a price for a large order? Call us or send a message.